| Applications: | For liquids only. Ideal for dirty fluids, has high tolerance to solids (up to 15%) and immune to viscosities to 400 cP. Mounts in any direction to measure flow in vertical (up/down) or horizontal pipe lines. |
| Flow Range: | 0.8 m3/h to 1 600 m3/h |
| Accuracy: | |
| Connection: | | DP-65: | DN40 to DN300 sandwich | | DP-500: | DN250 to DN500 flange (DIN, ANSI or others) | |
| Scale: | 10:1 |
| Materials: | Polyamide coated steel (Standard), SS-316L |
| Temperature: | -160ºC to +130/180ºC |
| Pressure: | 10 to 40 bar |
| Alarms: | Magnetic actuated micro switch, Inductive proximity switch |
| Transmitter: | 4-20mA, 4-20mA + totaliser, 4-20mA (EEx ia IIC T4), 4-20mA (EEx ia IIC T6), 3-15 psi |